Waferpedia

Comparison ledger

-407B-1-S-CES293 Robotversus2080 TCU Chiller

ABM -407B-1-S-CES293 Robot, Lam Research 2080 TCU Chiller, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
2080 TCU ChillerLam Research
OEMABMLam Research
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones—1998 Vintage date
Control system——
Generation——
FamilyABM -407B-1-S-CES293 RobotLam Research 2080 TCU Chiller
Specifications
ModelABM-407B-1-S-CES293[1]2080 TCU[2]
DescriptionROBOT[1]Dual Channel Chiller[2]
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[1]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[1]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[1]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[1]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[1]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[1]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[1]—
Manufacturer—Lam Research[2]
Height—55.25 in (140.34 cm)[2]
Width—23.75 in (60.33 cm)[2]
Depth—37.75 in (95.89 cm)[2]
Weight (empty reservoirs)—616 lbs (279.42 kg)[2]
Weight (full reservoirs)—690 lbs (312.98 kg)[2]
Upper channel temperature range—-15 to +80 °C[2]
Lower channel temperature range—-20 to +80 °C[2]
Temperature regulation—±1 °C (±0.3 °C typical) at rated static load[2]
Setpoint resolution—±0.1 °C[2]
Cooling power (lower channel at -20°C)—1000 W (3415 BTU/hr)[2]
Cooling power (upper channel at -15°C)—750 W (2561 BTU/hr)[2]
Heating power (upper/lower channel)—1600 W (5464 BTU/hr)[2]
Reservoir capacity (per reservoir)—4.23 gallons (16 liters)[2]
Ambient operating temperature—+10 to +40 °C[2]
Coolant composition—50/50 mixture of DI water and ethylene glycol (specific gravity 1.065 ±0.005)[2]
Power requirements—3-phase 208/230VAC at 50-60 Hz, 30 A with 10 kA Icu[2]
Fuses (EMO circuit)—(2) 1A, 250V SLO BLO[2]
Fuses (power supply)—(1) 0.75A, 250V SLO BLO[2]
Sound pressure level—<75 dBA[2]
Refrigerant type—R404A[2]
CE mark—Yes[2]
Lam part number—851-110195-020D[2]
Country of origin—USA[2]
Sources (2)Every fact above is drawn from these public sources
  1. [1]dealer listingsemistarcorp.com
  2. [2]fabsurplus.comfabsurplus.com