Comparison ledger
ABM -407B-2-S-CE-S293 Robot, Varian Clinac 21EX, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | Clinac 21EXVarian | |
|---|---|---|
| OEM | ABM | Varian |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | 1998 |
| Production run | — | 1998–2012 |
| Lifecycle | — | Discontinued |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | ABM -407B-2-S-CE-S293 Robot | Varian Clinac 21EX |
| Cited variants | — |
|
| Specifications | ||
| Model | ABM-407B-2-S-CE-S293[2] | Clinac 21EX[1] |
| Description | ROBOT[2] | — |
| Refurbished RTP RTA | AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2] | — |
| KLA-Tencor Spare Parts and Service | RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2] | — |
| Refurbished Isotropic Plasma Etcher | Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2] | — |
| Refurbished PECVD, ALD Equipment | Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2] | — |
| Refurbished Mask Aligner | Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2] | — |
| Refurbished Bonding | SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2] | — |
| Refurbished Wafer Prober | Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2] | — |
| Years Manufactured | — | 1998-2012[1] |
| Power Source | — | Klystron[1] |
| Photon Energy Configuration | — | 6 & 10/15/18/25 MV[1] |
| Max Dose Rate Photons | — | 600 MU/min[1] |
| Electron Energies | — | Yes[1] |
| Max Dose Rate Electrons | — | 1000 MU/min[1] |
| Multi-Leaf Collimator (MLC) | — | 80 leaves (field size 40x40 cm); 120 leaves (field size 40x40 cm, central 20 cm: 5 mm leaf width, outer 20 cm: 10 mm leaf width)[1] |
| Portal Imager (EPID) | — | LC250, aS500, aS1000 (optional)[1] |
| Treatment Delivery | — | 3D, IMRT, SRS/SBRT (optional)[1] |
| KV Imaging for IGRT | — | OBI (optional)[1] |
| Cone-Beam CT | — | Only with OBI[1] |
| iCBCT | — | No[1] |
| ART (Adaptive) | — | No[1] |
| VMAT | — | Only with OBI[1] |
| Stereotactic Radiosurgery | — | Optional Cones or mMLC[1] |
| Treatment Couch | — | Exact ETR, Exact (optional)[1] |
| Silhouette Option | — | Yes (for smaller room size)[1] |
| OEM | — | Varian[1] |
| Category | — | linear accelerator[1] |
| Photon energy configuration | — | 6 and 10/15/18/25 MV[1] |
| KV imaging for IGRT | — | OBI[1] |
| iCBCT (Iterative Cone Beam CT) | — | Yes[1] |
| Treatment delivery | — | 3D, IMRT, RapidArc, SRS/SBRT[1] |
| Treatment couch | — | Exact, Exact IGRT (optional)[1] |
| HyperArc upgrade option | — | Yes[1] |