Waferpedia

Comparison ledger

93000 SOCversusJ 750 S

Advantest 93000 SOC, Teradyne J 750 S, side by side. Every value shown is drawn from the cited encyclopedia entries.

Documented as functional equivalents— Same function class: Test & Probe, Unknown[1]
Side-by-side comparison of selected equipment models
Attribute
93000 SOCAdvantest
J 750 STeradyne
OEMAdvantestTeradyne
CategoryTest & ProbeTest & Probe
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyAdvantest 93000Teradyne J 750 S
Cited variants
  • Advantest 93000 SOC Tester[2]
—
Specifications
ConfigurationDedicated:[2]3 Wire + PE[1]
EMIGXIMAGE Grabber + DSP (4)[2]—
ACDC SDCabinet Primary Power Supply (3)[2]—
DCDC ACage Secondary Power Supply[2]—
DCDC DCage Secondary Power Supply (3)[2]—
C200e200MB/S Single Density (7)[2]—
C400e400MB/S Single Density (8)[2]—
HVPEHigh Voltage PE[2]—
GPDPSGeneral Purpose DPS 4 Ch 8V/8A (4)[2]—
MBAV8 4S4M AMCB 8 Units: 4 SRC + 4 MEAS[3]—
ACDC_PSCabinet Primary Power Supply (3)[3]—
DCDC_ACage Secondary Power Supply[3]—
DCDC_UCage Secondary Power Supply (3)[3]—
PS800Pin scale 800 MB/S (24)[3]—
MSDPS AMultisite DPS 8 Ch 8V/4A (4)[3]—
ACDC PSCabinet Primary Power Supply (8)[4]—
DCDC UCage Secondary Power Supply (8)[4]—
PS3600Pin scale 3600 MB/S[4]—
HCDPSHigh Current DPS 1Ch 4V/100A (2)[4]—
MBAV8 4S4M BMCB 8 Units: 4 SRC + 4 MEAS[5]—
Digital pin scale (PS800)800 MB/s[3]—
Digital pin scale (PS3600)3600 MB/s[4]—
Digital pin scale (C200e)200 MB/s Single Density[2]—
Digital pin scale (C400e)400 MB/s Single Density[2]—
AC module (MBAV8 4S4M A)MCB 8 Units: 4 SRC + 4 MEAS[3]—
AC module (MBAV8 4S4M B)MCB 8 Units: 4 SRC + 4 MEAS[5]—
High Voltage DPS (HVDPS)4Ch 22V/1A[4]—
High Current DPS (HCDPS)1Ch 4V/100A[4]—
General Purpose DPS (GPDPS)4 Ch 8V/8A[2]—
Multisite DPS (MSDPS A)8 Ch 8V/4A[3]—
Ultra High Current DPS (UHC4)Ultra High Current DPS[5]—
HVDPSHigh Voltage DPS 4Ch 22V/1A[4]—
Model93000 SOC[2]J 750 S[1]
MakeAdvantest[2]—
TypeSOC tester[6]—
Recorded file typeevent data record (EDL) file[6]—
Recordstest results and events[6]—
Phase—3 Phase[1]
Voltage—208 Vac[1]
Power Phase—3 Phase 3 Wire + PE[1]
Current—30 A[1]
Frequency—50/60 Hz[1]
OEM—Teradyne[1]
Equipment type—Tester[1]
Electrical requirement—3 Phase 3 Wire + PE, 30 A, 50/60 Hz, 208 Vac[1]

Plan your fab

Building a Test & Probe process? Get a complete equipment list.

Open the fab equipment planner →
Sources (6)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]Equipment inventory listing
  3. [3]inventory listing
  4. [4]inventory listing
  5. [5]inventory listing
  6. [6]patents.google.compatents.google.com