Waferpedia

Comparison ledger

DCS 1440 Automatic Cleaningversus1300 Series Safety

Disco DCS 1440 Automatic Cleaning, Thermo Fisher 1300 Series Safety, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
1300 Series SafetyThermo Fisher
OEMDiscoThermo Fisher
CategoryWet Processing / CleanWet Processing / Clean
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones—2026 Third-party support only
Control system——
Generation——
FamilyDisco DCS 1440 Automatic CleaningThermo Fisher 1300
Cited variants—
Specifications
Max workpiece sizeø200 mm / 250 mm square[1]—
Applicable tape frameDTF2-5, DTF2-6, DTF2-6-1, DTF2-8-1, DTF2-5-1, DTF2-8-1, DTF2-12, DTF2-12-1[1]—
Cleaning methodHigh pressure cleaning, atomizing cleaning (optional)[1]—
Number of cleaning sequences saved8[1]—
Spinner table rotational speed range100 ~ 3,000 min⁻¹[1]—
Spinner discharge pressure2.0 ~ 11.8 MPa[1]—
Power supply200 ~ 240 V AC ±10%, 3-phase[1]—
Power consumption during cleaning390 W[1]—
Power consumption during idling110 W[1]—
Max power2.6 kVA[1]—
Air pressure0.5 MPa, fluctuations ±0.01[1]—
Air consumption max flow rate216 L/min(ANR)[1]—
Clean air pressure0.5 MPa, fluctuations ±0.01[1]—
Average clean air consumption (high pressure cleaning)54 L/min(ANR)[1]—
Average clean air consumption (atomizing cleaning)98 L/min(ANR)[1]—
Cleaning water feed pressure0.2 ~ 0.4 MPa, fluctuations ±0.01[1]—
Cleaning water flow rate (high pressure cleaning)Max. 200 mL/min (at 11.8 MPa)[1]—
Cleaning water flow rate (atomizing cleaning)40 ~ 300 mL/min[1]—
Exhaust duct capacity3.0 m³/min[1]—
Machine dimensions (W x D x H)400 x 600 x 1,220 mm[1]—
Machine weightApprox. 130 kg[1]—
Green procurement supportRoHS compliant[1]—
Configuration—Class II[2]
Cabinet type—Class II, Type A2 biological safety cabinet[3]
Airflow compensation—SmartFlow airflow compensation system[3]
Motors—Dual DC motors[3]
Front window design—SmartClean front window design[3]
Control panel—Intuitive control panel with constant readout of downflow and inflow velocities and filter reserve status[3]
UV light—Programmable UV light[3]
SmartPort—SmartPort convenience for routing tubing and cables through the side walls[3]
Available widths—3-foot, 4-foot, 5-foot, and 6-foot sizes[3]
Front opening choices—8-inch or 10-inch front opening[3]
Filter specification—H14 HEPA filters, EN 1822, 99.995% @ MPPS[4]
Certification—NSF/ANSI 49, UL, CE[4]
Service valves—Up to 6 total, 3 on each side wall[4]

Plan your fab

Building a Wet Processing / Clean process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]epfl.chepfl.ch
  2. [2]inventory listing
  3. [3]thermofisher.comthermofisher.com
  4. [4]documents.thermofisher.comdocuments.thermofisher.com