Attribute
TCP 9600 MetalLam Research
100 ICP FluorineOxford Instruments
OEMLam ResearchOxford Instruments
CategoryEtchEtch
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyLam Research TCP 9600Oxford Instruments 100 ICP Fluorine
Specifications
ConfigurationSMIF[1]—
Supported wafer sizes150mm (6 inch) and 200mm[2]—
Process pressure range0 - 100 mTorr[3]—
Top electrode power0 - 1250 W[3]—
Lower electrode power0 - 1200 W[3]—
Process temperature55 °C[3]—
Process gasesCl2, BCl3, HBr, SF6, CF4, Ar, N2, O2, He[3]—
Endpoint detectionAdjustable monochromator[3]—
Wafer clampElectrostatic chuck (ESC) with helium backside cooling[4]—
Electrode gapFixed gap 8 inch TCP coil[4]—
Number of RF generators3 (AE RFG 1250)[4]—
Power supply requirements208V, 80A, 3-Phase, 50/60Hz[4]—
DSQ strip moduleIncluded[3]—
Software versionEnvision 1.6.1-012[4]—
Aluminum etch rate> 8000 Å/min[2]—
Aluminum non-uniformity+/- 15%[2]—
System uptimeTypically > 85%[2]—
Mean time to change (MTTC)12 hours[2]—
Mean time between failures (MTBF)> 125 hours[2]—
Mean time to repair (MTTR)< 4 hours[2]—
Etch Gases—SF6, CF4, O2, Ar, N2, CHF3, C4F8[6]
Cryo DRIE etch rate—up to 5 µm/min[6]
Wafer size—4 inch, 6 inch, 8 inch (with clamp change)[6]

Plan your fab

Building a Etch process? Get a complete equipment list.

Open the fab equipment planner →
Sources (6)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]semigroup.comsemigroup.com
  3. [3]semistarcorp.comsemistarcorp.com
  4. [4]solutions-on-silicon.comsolutions-on-silicon.com
  5. [5]waferpedia.comwaferpedia.com