Waferpedia

Comparison ledger

100 ICP FluorineversusPlasmalab80

Oxford Instruments 100 ICP Fluorine, Oxford Instruments Plasmalab80, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
100 ICP FluorineOxford Instruments
Plasmalab80Oxford Instruments
OEMOxford InstrumentsOxford Instruments
CategoryEtchEtch
Wafer size—up to 8-inch diameter wafers
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyOxford Instruments 100 ICP FluorineOxford Instruments Plasmalab80
Specifications
Etch GasesSF6, CF4, O2, Ar, N2, CHF3, C4F8[1]—
Cryo DRIE etch rateup to 5 µm/min[1]—
Wafer size4 inch, 6 inch, 8 inch (with clamp change)[1]—
Etch and deposition capabilities—Combined etch and deposition tool[2]
Etch processes—Bosch (gas chopping) or cryo processes[2]
Deposition materials—Silicon dioxide, silicon nitride, or mixed oxynitrides[2]
Wafer diameter—Up to 8-inch wafers[2]
Active etch/deposition region—Center 4 inches of the chamber[2]
Available gases—N2, N2O, O2, SF6, Ar (max flow 100 sccm); C4F8, SiH4, CH4 (max flow 20 sccm)[2]
Power—300 W RF and 300 W ICP[2]
Process pressure—4 to 100 mTorr[2]
Substrate temperature—-150 to 200 C[2]

Plan your fab

Building a Etch process? Get a complete equipment list.

Open the fab equipment planner →
Sources (2)Every fact above is drawn from these public sources
  1. [1]nanofab.utah.edunanofab.utah.edu
  2. [2]tmi.utexas.edutmi.utexas.edu