Waferpedia

Comparison ledger

300versusFalcon

PVA TePla 300, SUSS MicroTec Falcon, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
300PVA TePla
FalconSUSS MicroTec
OEMPVA TePlaSUSS MicroTec
CategoryResist ProcessingResist Processing
Wafer size75 mm to 100 mmWafer Backside Rinse
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyPVA TePla 300SUSS MicroTec Falcon
Cited variants
  • PVA TePla 300 AL (Autoload PC)[1]
  • PVA TEPLA 300 AL[1]
—
Specifications
Plasma typeHigh frequency plasma[2]—
Plasma frequency2.45 GHz[2]—
Plasma power200 to 1000 W[2]—
GasO2 (max. flow 500 ml/min)[2]—
ChamberQuartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[2]—
Wafer capacityQuartz holders for 25 wafers[2]—
Wafer size range75 mm to 100 mm[2]—
Micro-electronic compatibilityNot micro-electronic compatible[2]—
CategoryPlasma etcher (resist strip / surface activation)[2]—
Positive resist etch rate350 nm/min[2]—
CompatibilityNot micro-electronic compatible; gold allowed; Si, glass, Pyrex wafers[2]—
Power Range200 to 1000 W (or 0-1000 W)[2]—
Process GasesO2, Ar, N2, CF4[3]—
Chamber MaterialQuartz[2]—
Chamber Dimensions (internal)Diameter 245 mm x Depth 380 mm[2]—
Wafer Holder Capacity25 wafers[2]—
Wafer Size75 mm to 100 mm[2]—
Wafer Size (alternate)up to 6 inches[1]—
Process Pressure0.6 to 1.5 mbar[1]—
Restricted MaterialsMaterials that deteriorate in oxygen (Ag, Cu, Cr, Fe, etc.) should not be processed; no Cr or other metals in chamber[2]—
Microwave frequency2.45 GHz[2]—
Power range200 to 1000 W[2]—
Batch sizeUp to 25 wafers[2]—
Wafer diameter (standard carrier)75 mm to 100 mm[2]—
Process gasesO2, CF4, Ar, N2[3]—
Maximum O2 flow500 ml/min[2]—
Chamber dimensions (internal diameter x depth)245 mm x 380 mm[2]—
Chamber internal dimensionsDint. 245 mm x Prof. 380 mm[2]—
Gas 1O2 (max. flow 500 ml/min)[2]—
Resist strip etch rate350 nm/min depending on number of wafers[2]—
Faraday cageAvailable[2]—
Process gasO2 (max flow 500 ml/min)[2]—
Chamber dimensionsQuartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[2]—
Process typeHigh-frequency plasma[2]—
ApplicationsPhotoresist stripping; wafer surface cleaning; hydrophilic surface activation of plastics surfaces[2]—
Carrier capacityQuartz holders for 25 wafers[2]—
Not micro-electronic compatibleThis equipment is NOT micro-electronic compatible.[2]—
Configuration—Polyimid[4]
Cassette Elevators—2[4]
Developer Dispensers—2[4]
Wafer size—Wafer Backside Rinse[4]
Number of Hot Plates—0[4]
Number of Chill Plates—0[4]
Controller Type—Microprocessor Controller[4]
Power Requirements—380 V, 50/60 Hz, 3 Phase[4]

Plan your fab

Building a Resist Processing process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]polifab.polimi.itpolifab.polimi.it
  2. [2]epfl.chepfl.ch
  3. [3]nist.govnist.gov
  4. [4]inventory listing