Waferpedia

Comparison ledger

300versus211

PVA TePla 300, TEGAL 211, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
300PVA TePla
211TEGAL
OEMPVA TePlaTEGAL
CategoryResist ProcessingResist Processing
Wafer size75 mm to 100 mm—
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyPVA TePla 300TEGAL 211
Cited variants
  • PVA TePla 300 AL (Autoload PC)[1]
  • PVA TEPLA 300 AL[1]
—
Specifications
Plasma typeHigh frequency plasma[2]—
Plasma frequency2.45 GHz[2]—
Plasma power200 to 1000 W[2]—
GasO2 (max. flow 500 ml/min)[2]—
ChamberQuartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[2]—
Wafer capacityQuartz holders for 25 wafers[2]—
Wafer size range75 mm to 100 mm[2]—
Micro-electronic compatibilityNot micro-electronic compatible[2]—
CategoryPlasma etcher (resist strip / surface activation)[2]—
Positive resist etch rate350 nm/min[2]—
CompatibilityNot micro-electronic compatible; gold allowed; Si, glass, Pyrex wafers[2]—
Power Range200 to 1000 W (or 0-1000 W)[2]—
Process GasesO2, Ar, N2, CF4[3]—
Chamber MaterialQuartz[2]Aluminum[4]
Chamber Dimensions (internal)Diameter 245 mm x Depth 380 mm[2]—
Wafer Holder Capacity25 wafers[2]—
Wafer Size75 mm to 100 mm[2]—
Wafer Size (alternate)up to 6 inches[1]—
Process Pressure0.6 to 1.5 mbar[1]—
Restricted MaterialsMaterials that deteriorate in oxygen (Ag, Cu, Cr, Fe, etc.) should not be processed; no Cr or other metals in chamber[2]—
Microwave frequency2.45 GHz[2]—
Power range200 to 1000 W[2]—
Batch sizeUp to 25 wafers[2]—
Wafer diameter (standard carrier)75 mm to 100 mm[2]—
Process gasesO2, CF4, Ar, N2[3]—
Maximum O2 flow500 ml/min[2]—
Chamber dimensions (internal diameter x depth)245 mm x 380 mm[2]—
Chamber internal dimensionsDint. 245 mm x Prof. 380 mm[2]—
Gas 1O2 (max. flow 500 ml/min)[2]—
Resist strip etch rate350 nm/min depending on number of wafers[2]—
Faraday cageAvailable[2]—
Process gasO2 (max flow 500 ml/min)[2]—
Chamber dimensionsQuartz primary vacuum chamber, Dint. 245 mm x Prof. 380 mm[2]—
Process typeHigh-frequency plasma[2]—
ApplicationsPhotoresist stripping; wafer surface cleaning; hydrophilic surface activation of plastics surfaces[2]—
Carrier capacityQuartz holders for 25 wafers[2]—
Not micro-electronic compatibleThis equipment is NOT micro-electronic compatible.[2]—
Refurbished RTP RTA—AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[4]
KLA-Tencor Spare Parts and Service—RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[4]
Refurbished Isotropic Plasma Etcher—Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[4]
Refurbished PECVD, ALD Equipment—Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[4]
Refurbished Mask Aligner—Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[4]
Refurbished Bonding—SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[4]
Refurbished Wafer Prober—Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[4]
Process Type—Plasma Asher/Etcher[5]
Wafer Size (max)—3 inch[5]
Form Factor—Table top[5]
Chamber Internal Dimensions—6 x 6 x 3.75 inches[4]
Timer Range—0-99 minutes[5]

Plan your fab

Building a Resist Processing process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]polifab.polimi.itpolifab.polimi.it
  2. [2]epfl.chepfl.ch
  3. [3]nist.govnist.gov
  4. [4]dealer listingsemistarcorp.com
  5. [5]jmind.comjmind.com