Comparison ledger
Signatone 1070, Signatone CM 210, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 1070Signatone | CM 210Signatone |
|---|---|---|
| OEM | Signatone | Signatone |
| Category | Test & Probe | Test & Probe |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Signatone 1070 | Signatone CM 210 |
| Specifications | ||
| Make | Signatone[1] | — |
| Model | 1070[1] | — |
| Chuck XY Stage Travel Range | — | 205 mm x 205 mm (8.07 x 8.07 in)[2] |
| Chuck XY Travel Resolution (Standard) | — | 14 μm Per Degree of Knob Rotation[2] |
| Chuck XY Travel Resolution (Fine) | — | 1.5 μm Per Degree of Knob Rotation[2] |
| Chuck Z Stage Travel Range | — | 2.5 mm (0.01 in)[2] |
| Chuck Z Stage Repeatability | — | ± 1.0 μm[2] |
| Chuck Theta Stage Travel Range | — | ± 11° (22°)[2] |
| Chuck Theta Stage Accuracy | — | < 1.0 μm (measured at the edge of the 200 mm chuck)[2] |
| Probe Platen Material | — | Nickel Plated Steel (Aluminum optional)[2] |
| Probe Platen Dimensions | — | L = 580mm x W = 637mm x H = 12.7mm[2] |
| Max Number of Micro Positioners | — | 10x DC/HV or 2x RF + 4x DC or 4x RF + 2x DC or 2x CAP + 4x DC[2] |
| Contact Repeatability | — | < 1 μm (0.04 mils) by Manual Control[2] |
| Standard Wafer Chuck Diameter | — | 203 mm[2] |
| Standard Wafer Chuck Surface Planarity | — | ±6.5 μm[2] |
| Standard Wafer Chuck Rigidity | — | <3 μm / 10N at edge of the chuck[2] |
| Coax Chuck Operation Voltage | — | -200V to +200V DC[2] |
| Coax Chuck Max Voltage (Chuck to GND) | — | 500 V DC[2] |
| Coax Chuck Isolation | — | > 150 GΩ[2] |
| Triax Chuck Isolation (Force to Guard @ 10V) | — | > 2 TΩ[2] |
| System Dimensions (Optional Table) | — | 660 x 889 x 610 mm (26 x 35 x 24 in)[3] |
| System Weight (Optional Table) | — | 109 kg (240 lbs)[3] |
| System Dimensions Including Table | — | 863 x 1085 x 1370 mm (34 x 42.7 x 53.95 in)[3] |
| System Weight Including Table | — | 385 kg (849 lbs)[3] |
| Available Thermal Chuck Options | — | Standard Hot (25°C to 300°C), Hot/Triax (25°C to 200°C), Hot/3kV Triax (25°C to 200°C)[2] |
Plan your fab
Building a Test & Probe process? Get a complete equipment list.
Open the fab equipment planner →