Waferpedia

Comparison ledger

7700 Series ICP-MSversus1050 UV-VIS

Agilent 7700 Series ICP-MS, Perkin Elmer 1050 UV-VIS, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
1050 UV-VISPerkin Elmer
OEMAgilentPerkin Elmer
CategoryPrecision OpticsPrecision Optics
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones2026 OEM support ended—
Control system——
Generation——
FamilyAgilent 7700Perkin Elmer 1050 UV-VIS
Cited variants—
Specifications
ConfigurationAgilent 7700 Series ICP/MS[3]—
Mass AnalyzerQuadrupole[1]—
Mass Range2-260 amu[4]—
Scan Speed100 milliseconds (for full mass range)[4]—
DetectorElectron Multiplier (pulse and analog modes)[4]—
Sensitivity (7700x) Li (7)50 Mcps/ppm[1]—
Sensitivity (7700x) Y (89)160 Mcps/ppm[1]—
Sensitivity (7700x) Tl (205)80 Mcps/ppm[1]—
Sensitivity (7700s) Li (7)50 Mcps/ppm[1]—
Sensitivity (7700s) Y (89)240 Mcps/ppm[1]—
Sensitivity (7700s) Tl (205)120 Mcps/ppm[1]—
Sensitivity (7700e) Li (7)20 Mcps/ppm[2]—
Sensitivity (7700e) Y (89)80 Mcps/ppm[2]—
Sensitivity (7700e) Tl (205)40 Mcps/ppm[2]—
Background on-mass (No gas, 9 amu) - 7700x<2 cps[1]—
Background on-mass (No gas, 9 amu) - 7700s<3 cps[1]—
Background on-mass (He cell gas, 9 amu) - 7700x<0.5 cps[1]—
Background on-mass (He cell gas, 9 amu) - 7700s<0.5 cps[1]—
Oxide ratio (CeO/Ce) - 7700x<1.5%[1]—
Oxide ratio (CeO/Ce) - 7700s<3%[1]—
Doubly-charged ratio (Ce2+/Ce) - 7700x<3%[1]—
Doubly-charged ratio (Ce2+/Ce) - 7700s<6%[1]—
Short-term stability (20 min, %RSD)<3% (7700x, 7700s)[1]—
Long-term stability (2 hours, %RSD)<4% (7700x, 7700s)[1]—
Power SupplySingle Phase, 200-240V, 50/60Hz, 30A[1]—
Dimensions (mainframe, W x D x H)730 x 620 x 595 mm[1]—
Weight (mainframe)115 kg[1]—
Argon Gas Supply (minimum purity)99.99%[1]—
Argon Gas Supply (maximum flow rate)20 L/min[1]—
Argon Gas Supply (supply pressure)500-700 kPa[1]—
Sensitivity (Y 89)160 Mcps/ppm (7700x) / 240 Mcps/ppm (7700s)[1]—
Sensitivity (Tl 205)80 Mcps/ppm (7700x) / 120 Mcps/ppm (7700s)[1]—
Oxide ratio (CeO/Ce)<1.5% (7700x) / <3% (7700s)[1]—
Mainframe dimensions (W x D x H)730 mm x 620 mm x 595 mm[1]—
Mainframe weight115 kg[1]—
RF power range500 W to 1600 W, in steps of 10 W[2]—
Sampling depth3 to 28 mm[1]—
Asset ID—82948[5]
Last Confirm Date—August 23, 2024[5]
Manufacturer—Perkin Elmer[5]
Model—1050[5]
Instrument type—Spectrometer[5]
Use—Analyzing ultraviolet and visible light absorption spectra[5]

Plan your fab

Building a Precision Optics process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]ietltd.comietltd.com
  2. [2]antpedia.comantpedia.com
  3. [3]inventory listing
  4. [4]engineering.purdue.eduengineering.purdue.edu
  5. [5]waferpedia.comwaferpedia.com