Waferpedia

Comparison ledger

0010-03485 Magnet AssyversusMPA 600 FA

Applied Materials 0010-03485 Magnet Assy, Canon MPA 600 FA, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
0010-03485 Magnet AssyApplied Materials
OEMApplied MaterialsCanon
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0010-03485 Magnet AssyCanon MPA 600
Specifications
ConfigurationWP AL 300mm PVD[1]Upgraded to 150 mm compatibility[5]
OEMApplied Materials[1]—
Model0010-03485[1]—
DescriptionMAGNET ASSY, WP AL 300MM PVD[2]—
ProcessPVD[3]—
Wafer size300mm[4]—
VersionSpares[4]—
Part Number0010-03485[1]—
ManufacturerApplied Materials[1]—
Process TypePVD (Physical Vapor Deposition)[1]—
Application (Material)Aluminum (AL)[1]—
Wafer Diameter (associated)300 mm[1]—
Type—1X mirror projection auto feeder / mask aligner[6]
Auto feeder—Single or double, cassette to cassette, backside wafer handling[6]
Wafer sizes—4 inch, 5 inch, 6 inch[6]
Mask sizes—5 inch, 6 inch, 7 inch[6]
Resolution—1.5 um (using positive resist)[6]
Illumination—2 kW high pressure mercury lamp[6]
Wavelengths used—365 nm (i-line), 405 nm (h-line), 436 nm (g-line)[6]
Intensity—At 1800 watts power output: 4 inch wafer more than 700 mW, 5 inch wafer more than 650 mW, 6 inch wafer more than 600 mW[6]
Intensity / exposure uniformity—Within plus/minus 3%[6]
Constant temperature control—Monitors and controls system temperature within plus/minus 0.3 degrees C[6]
Distortion control—PDC matic distortion control[6]
Automatic alignment—HeNe 633 nm laser beam scanning alignment[6]
Alignment modes—Spot beam / sheet beam[6]
Alignment accuracy—3sigma <= 0.54 um[6]
Required facilities—200 VAC, 3Phase, 6 kVA, 50/60Hz; Air Supply(CTC): 200 VAC, 3Phase, 8 kVA, 50/60Hz; CDA pressure minimum 6.5 kg/cm2, flow rate 130 lit/min; Vacuum 50 cmHg or more; Exhaust flow for illuminator 6.5 m/sec to 9.5 m/sec[6]
Compatibility upgrade—Upgraded to 150 mm compatibility[7]
Monitor—Monitor not included[7]
Vintage—1991 vintage[7]
Wafer handling—Single or double, cassette to cassette, backside wafer handling[7]
Tool type—1X mirror projection mask aligner[7]
Temperature control—Monitors and controls system temperature within plus/minus 0.3 degrees C[7]
Power / electrical—200 VAC, 3Phase, 6 kVA, 50/60Hz[7]
Air supply (CTC)—200 VAC, 3Phase, 8 kVA, 50/60Hz[7]
CDA pressure—Minimum 6.5 kg/cm2, flow rate 130 lit/min[7]
Vacuum—50 cmHg or more[7]
Exhaust flow for illuminator—6.5 m/sec to 9.5 m/sec[7]
Sources (7)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]semistarcorp.comsemistarcorp.com
  3. [3]layla-ec.comlayla-ec.com
  4. [4]fabsurplus.comfabsurplus.com
  5. [5]inventory listing
  6. [6]servtechinc.comservtechinc.com
  7. [7]waferpedia.comwaferpedia.com