05 LHP 151versusFTIR

Melles Griot 05 LHP 151, Perkin Elmer FTIR, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
05 LHP 151Melles Griot
FTIRPerkin Elmer
OEMMelles GriotPerkin Elmer
CategoryPrecision OpticsPrecision Optics
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyMelles Griot 05Perkin Elmer FTIR
Cited variants—
  • Frontier FTIR[1]
  • Spectrum Two FTIR[2]
  • Spectrum 3 Tri-Range MIR/NIR/FIR Spectrometer[3]
  • Spotlight Aurora FTIR Microscope[3]
  • PerkinElmer Frontier FTIR[1]
  • PerkinElmer Spectrum Two FTIR[2]
  • PerkinElmer Spectrum 3 FTIR[3]
Specifications
ConfigurationWith 05 LPL 340 Power Supply (Does not power on)[4]—
Equipment typeLaser[4]—
MakeMelles Griot[4]—
Model05 LHP 151[4]—
Power stateDoes not power on[4]—
Spectral range (Frontier)—mid-IR 8300–350 cm⁻¹, far-IR 700–30 cm⁻¹[1]
Best resolution (Frontier)—0.4 cm⁻¹[1]
Spectral range (Spectrum Two)—8300–350 cm⁻¹[2]
Signal-to-noise ratio (Spectrum Two standard LiTaO₃)—9,300:1[2]
Signal-to-noise ratio (Spectrum Two Peltier-stabilized DTGS)—14,500:1[2]
Operating temperature range (Spectrum Two)—5–45 °C[2]
External dimensions (Spectrum Two, Peltier stabilizer, KBr)—15"W x 18"D x 20"H[2]
Detector (Spectrum Two standard)—LiTaO₃ (lithium tantalate) MIR detector[2]
Interferometer (Spectrum Two)—Dynascan fixed mirror-pair interferometer[2]
OpticsGuard (Spectrum Two)—Protects instrument from humidity; long-life desiccant[2]
Atmospheric Vapor Compensation (Spectrum Two)—Real-time compensation for CO₂ and H₂O[2]
Absolute Virtual Instrument (AVI) option (Spectrum Two)—Uses gas phase spectra for accurate calibration and wavenumber standardization[2]
Spectral Range (Mid-IR, Frontier FTIR)—8300–350 cm−1[1]
Spectral Range (Far-IR, Frontier FTIR)—700–30 cm−1[1]
Best Resolution (Frontier FTIR)—0.4 cm−1[1]
Spectral Range (Spectrum Two FTIR)—8300–350 cm−1[2]
Signal-to-Noise Ratio (Standard detector, Spectrum Two)—9,300:1 (LiTaO3)[2]
Signal-to-Noise Ratio (Peltier stabilized detector, Spectrum Two)—14,500:1[2]
Detector (Spectrum Two)—LiTaO3 (lithium tantalate) MIR detector[2]

Plan your fab

Building a Precision Optics process? Get a complete equipment list.

Open the fab equipment planner →