Waferpedia

Agilent

1200 HPLC

Agilent 12xx family
Research Quality: 40% complete
1200 HPLC — Inventory photo
Fig. 011200 HPLCInventory photo[1]

Vacuum

Binary Pump G1312A[1]

Optics

10°C below ambient to 100°C[2]

What it is

The Agilent 1200 HPLC stack can include a degasser, pump, autosampler, thermostatted column compartment, detector, and data system.[1][2][4][3]

How it works

The Agilent 1200 HPLC drives liquid mobile phase through a column, injects a measured sample volume, controls column temperature, and detects compounds as they elute.[2]

The Agilent 1200 platform uses modular solvent delivery and can operate with isocratic or gradient mixing configurations.[2][3][5]

The Agilent 1200 platform supports detector types that include diode-array, variable-wavelength, fluorescence, refractive-index, and evaporative light-scattering detection.[2][5]

Where it fits in the process flow

The Agilent 1200 HPLC is used for routine analysis, method development, and quality control workflows.[5][3]

Applications

The Agilent 1200 HPLC is used in pharmaceutical analysis, environmental analysis, food and beverage testing, clinical and forensic screening, cannabis testing, natural products work, and chemical and materials analysis.[2]

The Agilent 1200 HPLC supports assay testing, impurity analysis, dissolution testing, contaminant and residue analysis, additive and vitamin analysis, potency testing, botanical actives analysis, drug monitoring, purity analysis, and additive measurement.[2]

What do the numbers mean?

Vacuum & pumping6

Binary Pump G1312A[1]
Accurate?
Included modules
Degasser, Binary Pump, DAD, TCC, ALS, FC/ALS Therm[1]
Accurate?
Includes
Degasser, Pump, Autosampler, Thermostatted Column Compartment, Detector, Data system[2]
Accurate?
Maximum pressure
up to 600 bar[2]
Accurate?
Maximum operating pressure
400 bar / 5880 psi (standard 1200 Series) / 600 bar / 8700 psi (1200 Series RRLC)[3]
Accurate?
Flow rate range
0.001 to 10.0 mL/min (standard pumps) / up to 5.0 mL/min (RRLC binary pump SL)[3]
Accurate?

Optics & imaging3

Column compartment temperature range
10°C below ambient to 100°C[2]
Accurate?
Detector options
DAD, VWD, FLD, RID, ELSD[2]
Accurate?
Detector wavelength range
190 to 950 nm (DAD) / 190 to 600 nm (VWD)[3]
Accurate?

Configuration & options9

Degasser B1379B[1]
Accurate?
DAD G1315D[1]
Accurate?
TCC G1316A[1]
Accurate?
ALS G1329A[1]
Accurate?
FC/ALS Therm G1330B[1]
Accurate?
Make
Agilent[1]
Accurate?
Model
1200[1]
Accurate?
System type
HPLC system[2]
Accurate?
Flow rate range
0.05 to 5 mL/min[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationBinary Pump G1312A[1]
  • Included modulesDegasser, Binary Pump, DAD, TCC, ALS, FC/ALS Therm[1]
  • IncludesDegasser, Pump, Autosampler, Thermostatted Column Compartment, Detector, Data system[2]
  • Maximum pressureup to 600 bar[2]
  • Maximum operating pressure400 bar / 5880 psi (standard 1200 Series) / 600 bar / 8700 psi (1200 Series RRLC)[3]
  • Flow rate range0.001 to 10.0 mL/min (standard pumps) / up to 5.0 mL/min (RRLC binary pump SL)[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What modules can the Agilent 1200 HPLC stack include?

The Agilent 1200 HPLC stack can include a degasser, pump, autosampler, thermostatted column compartment, detector, and data system.[1][2][4][3]

What does the Agilent 1200 HPLC do in a chromatographic run?

The Agilent 1200 HPLC drives mobile phase through the column, injects a measured sample volume, controls column temperature, and detects compounds as they elute.[2]

What types of analytical work use the Agilent 1200 HPLC?

The Agilent 1200 HPLC is used in pharmaceutical, environmental, food and beverage, clinical and forensic, cannabis, natural products, and chemical and materials applications.[2]

Not publicly documented

The following facts about the 1200 HPLC are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 1200 HPLC are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 1200 HPLC are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 1200 HPLC are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 1200 HPLC are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 1200 HPLC is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]gentechscientific.com — gentechscientific.comgentechscientific.com
  3. [3]specatlashub.com — specatlashub.comspecatlashub.com
  4. [4]Agilent 1200 HPLC System - Conquer Scientific — conquerscientific.comconquerscientific.com
  5. [5]https://www.syntechinnovation.com/images/catalog/advance-analytical/8chromatography/HPLC_Brochure.pdf — syntechinnovation.comsyntechinnovation.com
Was this page accurate?