Waferpedia

Agilent

3562 A Dynamic Signal Analyzer

Agilent 3562 A Dynamic Signal Analyzer family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Agilent 3562A Dynamic Signal Analyzer is a dual-channel fast-Fourier transform-based analyzer. The Agilent 3562A Dynamic Signal Analyzer operates over a dc-to-100 kHz frequency range. The Agilent 3562A Dynamic Signal Analyzer includes a built-in signal source.[1][2][3]

3562 A Dynamic Signal Analyzer — Inventory photo
Fig. 013562 A Dynamic Signal AnalyzerInventory photo[4]

Power

dc to 100 kHz[2]

Performance

±0.15 dB[1]

What it is

The HP 3562A is a dual-channel, fast Fourier transform-based dynamic signal analyzer. The instrument provides analysis capabilities in both the time and frequency domains.[1][2]

The HP 3562A covers a frequency range from dc to 100 kHz. The analyzer has a measurement range of 150 dB and a dynamic range of 80 dB.[2][3]

What do the numbers mean?

Power & electrical2

Frequency range
dc to 100 kHz[2]2 sources
Accurate?
Zoom frequency resolution
25.6 µHz[1]
Accurate?

Performance3

Single channel accuracy
±0.15 dB[1]
Accurate?
Frequency response magnitude accuracy
±0.1 dB[1]
Accurate?
Frequency response phase accuracy
±0.5°[1]
Accurate?

Control & software1

Direct control
Disc drives and HP-GL plotters[2]
Accurate?

Configuration & options12

Manufacturer
Agilent[7]
Accurate?
Model
3562 A[7]
Accurate?
Instrument type
Dynamic Signal Analyzer[7]
Accurate?
Channel count
Dual-channel[2]
Accurate?
Analysis architecture
Fast-Fourier transform-based[2]
Accurate?
Measurement range
150 dB[2]2 sources
Accurate?
Dynamic range
80 dB[2]2 sources
Accurate?
Built-in signal source
Noise and sine signals[2]2 sources
Accurate?
Analysis functions
Network analysis, spectrum analysis, transient analysis, waveform recording, frequency response analysis, and modulation analysis[2]
Accurate?
Time record points
2048-point[2]
Accurate?
Number of frequency lines
801-line[2]
Accurate?
Demodulation
AM, FM, PM[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Frequency rangedc to 100 kHz[2]
  • Zoom frequency resolution25.6 µHz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the measurement dynamic range of the HP 3562A?

The HP 3562A offers a 150 dB measurement range and 80 dB dynamic range.[2][3]

What signal source is built into the HP 3562A?

The HP 3562A includes a built-in signal source that provides noise and sine signals.[2]

What is the frequency resolution of the HP 3562A?

The HP 3562A provides zoom analysis with frequency resolution to 25.6 microhertz.[2]

Not publicly documented

The following facts about the 3562 A Dynamic Signal Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 3562 A Dynamic Signal Analyzer are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 3562 A Dynamic Signal Analyzer are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 3562 A Dynamic Signal Analyzer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 3562 A Dynamic Signal Analyzer are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 3562 A Dynamic Signal Analyzer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (7)Every fact above is drawn from these public sources
  1. [1]manualslib.com — manualslib.commanualslib.com
  2. [2]testequipmentdepot.com — testequipmentdepot.comtestequipmentdepot.com
  3. [3]Agilent/ HP 3562A Dynamic Signal Analyzer, Dual-Channel, 64 µHz to 100 kHz - Calright Instruments — calright.comcalright.com
  4. [4]Inventory photo
  5. [5]Inventory photo
  6. [6]Inventory photo
  7. [7]Equipment inventory listing
Was this page accurate?

Last updated Sep 30, 2026.

Compare with similar tools

View all →