The Agilent 700 ICP-OES is an optical emission spectrometer. The Agilent 700 ICP-OES is a full-spectrum direct-reading inductively coupled plasma optical emission spectrometer. The Agilent 700 ICP-OES has a wavelength range of 175–785 nm.[1]
The Agilent 700 ICP-OES is used after sample preparation to quantify elemental composition in liquid analytical workflows.[1]
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The Agilent 700 ICP-OES covers 175 to 785 nm continuously and without spectral gaps.[1]
The Agilent 700 ICP-OES uses a high-resolution CCD detector with more than one million pixels and anti-blooming architecture.[1]
The Agilent 700 ICP-OES is given with an RF generator frequency of 40.68 MHz.[1]
The Agilent 700 ICP-OES is given with plasma output power from 700 to 1700 W.[1]
The Agilent 700 ICP-OES is given with a 0.4 m focal length and a 97.4 lines per mm echelle grating.[1]
The following facts about the 700 ICP-OES are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 700 ICP-OES are on record.
Answerable by: OEM historical records or a trade-press announcement
No publicly documented variants, configuration options, or revision breakpoints of the 700 ICP-OES are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the 700 ICP-OES are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the 700 ICP-OES are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the 700 ICP-OES is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No research found yet — worked with this tool? Share what you know.