Agilent
The Agilent / Varian 7500 A is an inductively coupled plasma mass spectrometer (ICP-MS). The Agilent / Varian 7500 A uses a digital drive 27 MHz ICP RF generator and hyperbolic profile quadrupole rods.[1]

The Agilent 7500 A is an inductively coupled plasma mass spectrometer (ICP-MS) designed for trace element analysis.[1]
The Agilent 7500 A ICP-MS uses a Peltier-cooled spray chamber to introduce liquid samples into the plasma.[1]
The instrument features a fully automatic, computer-controlled torch position in all three axes and a ShieldTorch System (STS).[1]
The mass analyzer uses hyperbolic profile quadrupole rods driven by a highest-frequency, digitally synthesized 3 MHz RF Quadrupole Driver.[1]
Detection is performed by a simultaneous dual mode detector with an exclusive high-speed amplifier.[1]
In semiconductor manufacturing, ICP-MS instruments are used for trace metal analysis to monitor contamination in process chemicals, deionized water, and on wafer surfaces.
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The following facts about the 7500 A ICP-MS are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 7500 A ICP-MS are on record.
Answerable by: OEM historical records or a trade-press announcement
No publicly documented variants, configuration options, or revision breakpoints of the 7500 A ICP-MS are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the 7500 A ICP-MS are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the 7500 A ICP-MS are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the 7500 A ICP-MS is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No research found yet — worked with this tool? Share what you know.
Last updated Oct 8, 2026.