The Agilent G 8481 A is a recirculating chiller used with Agilent ICP-OES and ICP-MS instruments. The G 8481 A chiller has a factory-reset procedure and is set to a temperature of 20 °C.[1]
The Agilent G 8481 A is used as a cooling component for Agilent ICP-OES and ICP-MS instruments.[1]
The Agilent G 8481 A has a main power switch on the rear panel and a soft power button on the front panel, along with a Select/Set knob and a front display.[1]
A factory reset of the chiller is performed by placing the rear main power switch in the off position, then pressing and holding the front soft power button while returning the rear switch to the on position.[1]
After a factory reset, the temperature setpoint must be adjusted to 20 °C by pressing the Select/Set knob, rotating it to display the desired value, and pressing again to accept.[1]
The chiller's main board contains two accessible fuses; to inspect or replace them, the top cover is removed by unfastening screws on the rear and front of the unit.[1]
The Agilent G 8481 A is specifically used on Agilent ICP-OES and ICP-MS instruments.[1]
The Agilent G 8481 A chiller is used with Agilent ICP-OES and ICP-MS instruments for elemental analysis of liquid samples.[1]
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The following facts about the G 8481 A Chiller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
Fewer than 3 independently cited specifications for the G 8481 A Chiller are on record; the remainder await public documentation.
Answerable by: an OEM datasheet, a cleanroom equipment inventory, or an engineer who operated or installed it
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the G 8481 A Chiller are on record.
Answerable by: OEM historical records or a trade-press announcement
No publicly documented variants, configuration options, or revision breakpoints of the G 8481 A Chiller are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the G 8481 A Chiller are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the G 8481 A Chiller are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
No research found yet — worked with this tool? Share what you know.
Last updated Sep 29, 2026.