Waferpedia

Denton Vacuum

Discovery 18

The Denton Discovery 18 is a sputter deposition system for metals, alloys, and insulating thin films. The Discovery 18 includes a 6-inch diameter stage and provides substrate rotation. The Discovery 18 is pumped by cryo and turbo pumps to 1 x 10^-7 Torr.[1]

Discovery 18 — nanofab.utah.edu
Fig. 01Discovery 18nanofab.utah.edu[1]

Wafer size

6-inch diameter stage

Power

2 RF power supplies[1]

Vacuum

Cryo and turbo pumped[1]

Performance

+/- 10%[1]

Gas delivery

200 sccm (no APC valve)[1]

What it is

General reference — not yet source-verified

Sputter deposition systems are used to deposit thin films of metals, dielectrics, and other materials onto substrates in a vacuum environment. The Discovery 18 belongs to this class of physical vapor deposition equipment, commonly found in research and production cleanrooms for semiconductor, MEMS, and optical device fabrication.

How it works

General reference — not yet source-verified

Sputter deposition works by creating a plasma of inert gas, typically argon, in a vacuum chamber. Ions from the plasma are accelerated toward a target material, dislodging atoms that then travel to and condense on the substrate, forming a thin film. The process can be driven by DC for conductive targets or RF for insulating targets.

Where it fits in the process flow

General reference — not yet source-verified

In a typical microfabrication process flow, sputter deposition is performed after photolithography when a patterned metal or dielectric layer is required. The deposited film can be subsequently patterned by lift-off or by etching. The Discovery 18 is used for depositing thin films of metals, alloys, and insulating materials as part of interconnect metallization, contact layers, and device passivation.

Applications

General reference — not yet source-verified

Applications for sputter-deposited films include ohmic contacts, Schottky barriers, diffusion barriers, transparent conductive electrodes, magnetic films, and optical coatings. The flexibility to deposit both conductors and insulators makes the tool suitable for a variety of device and research uses.

  • Sputter deposition of metals
  • Sputter deposition of alloys
  • Sputter deposition of insulating thin films

What do the numbers mean?

Power & electrical5

RF power supplies
2 RF power supplies[1]
Accurate?
DC power supply
Switchable DC power supply[1]
Accurate?
RF power supplies
2[1]
Accurate?
DC power supply
Switchable[1]
Accurate?
Power supplies
2 RF power supplies; switchable DC power supply[1]
Accurate?

Vacuum & pumping12

Pump system
Cryo and turbo pumped[1]
Accurate?
Base pressure
1 x 10^7 Torr[1]
Accurate?
Argon pressure range
3-15 mT controllable with 200 sccm MFC controller[1]
Accurate?
Pumping system
Cryo and turbo pumped[1]
Accurate?
Argon pressure range
3-15 mT[1]
Accurate?
Base pressure
Cryo and turbo pumped to 1 x 10^-7 Torr[1]
Accurate?
Argon pressure range
3-15 mT controllable with 200 sccm MFC controller (no APC valve)[1]
Accurate?
High vacuum pump
140 l/s Turbomolecular Pump[2]
Accurate?
Mechanical pump
11 cfm[2]
Accurate?
High vacuum gauge
Digital Cold Cathode Auto-Ranging[2]
Accurate?
Control type
PLC Control of Auto Pump Sequence[2]
Accurate?
Chamber viewpoints
(1) 4.0" Diameter High Vacuum Valve Horizontal, 5.75" Diameter Bellows Sealed[2]
Accurate?

Wafer handling6

Substrate rotation uniformity
+/- 10%[1]
Accurate?
Substrate heating
Up to 200 C[1]
Accurate?
Substrate rotation
Yes[1]
Accurate?
Substrate stage size
6-inch diameter stage[1]
Accurate?
Substrate rotation
Substrate rotation +/- 10% Uniformity[1]
Accurate?
Substrate heating
Substrate heat up to 200 C[1]
Accurate?

Gas & chemistry1

MFC controller
200 sccm (no APC valve)[1]
Accurate?

Optics & imaging3

Film thickness range
From a few nm to hundreds of nm[1]
Accurate?
Film thickness range
A few nm to hundreds of nm[1]
Accurate?
Film thickness control
Controllable from a few nm to hundreds of nm[1]
Accurate?

Performance1

Uniformity
+/- 10%[1]
Accurate?

Control & software1

Control cabinet
Single 19" Standard EIA Rack, with Single Point Power Connection[2]
Accurate?

Dimensions & facilities1

Floor space
96" Wide x 48" Deep[2]
Accurate?

Configuration & options17

Deposition type
Sputter deposition of metals, alloys, and insulating thin films[1]
Accurate?
Cathodes
Three 3-inch diameter confocal cathodes[1]
Accurate?
Co-sputter capability
Yes[1]
Accurate?
Reactive sputtering
Available with nitrogen or oxygen[1]
Accurate?
Stage diameter
6-inch diameter stage[1]
Accurate?
Liftoff deposition
Available with sputter power[1]
Accurate?
Number of cathodes
3[1]
Accurate?
Cathode diameter
3 inches[1]
Accurate?
Co-sputtering capability
Yes[1]
Accurate?
Reactive sputtering
Available (Nitrogen or Oxygen)[1]
Accurate?
Stage diameter
6 inches[1]
Accurate?
Deposition technique
Sputter deposition of metals, alloys, and insulating thin films (user configurable)[1]
Accurate?
Co-sputter capability
Co-sputter capable[1]
Accurate?
Reactive sputtering
Reactive sputtering available (Nitrogen or Oxygen)[1]
Accurate?
Chamber material
304L SS, 18" Diameter x 13.5" Deep[2]
Accurate?
Baseplate material
304L SS, 20" Diameter[2]
Accurate?
Feedthroughs
Baseplate (15) 1.0", (2) 2.75" Conflats, (2) 1.33" Conflats[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Alternatives

Tools documented as functional equivalents — same process step and wafer size, from a different manufacturer. Each equivalence cites its source.

  • siblingDenton Vacuum 635— Listed on the same equipment page under deposition alongside Denton 635.source[3]
  • siblingDenton Vacuum 635LL— Listed alongside the 635LL in the sputtering section as another Denton sputtering tool.source[4]

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • RF power supplies2 RF power supplies[1]
  • DC power supplySwitchable DC power supply[1]
  • Pump systemCryo and turbo pumped[1]
  • Base pressure1 x 10^7 Torr[1]
  • Argon pressure range3-15 mT controllable with 200 sccm MFC controller[1]
  • RF power supplies2[1]
  • DC power supplySwitchable[1]
  • Pumping systemCryo and turbo pumped[1]
  • Argon pressure range3-15 mT[1]
  • MFC controller200 sccm (no APC valve)[1]
  • Power supplies2 RF power supplies; switchable DC power supply[1]
  • Base pressureCryo and turbo pumped to 1 x 10^-7 Torr[1]
  • Argon pressure range3-15 mT controllable with 200 sccm MFC controller (no APC valve)[1]
  • High vacuum pump140 l/s Turbomolecular Pump[2]
  • Mechanical pump11 cfm[2]
  • High vacuum gaugeDigital Cold Cathode Auto-Ranging[2]
  • Control typePLC Control of Auto Pump Sequence[2]
  • Chamber viewpoints(1) 4.0" Diameter High Vacuum Valve Horizontal, 5.75" Diameter Bellows Sealed[2]

Where are the manuals?

Publicly hosted documents referencing this tool, linked at their original location. Hosted by the linked institutions — availability may change.

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What types of materials can be deposited with this system?

The system can deposit metals, alloys, and insulating thin films, including Ag, Al, Au, C, Co, Cr, Cu, Ge, Ir, Fe, Ni, Pd, Pt, Si, Ta, Ti, V, W, and various oxides and ceramics.[1]

What is the maximum substrate size and uniformity?

The stage is six inches in diameter with substrate rotation, providing plus or minus 10% uniformity.[1]

What pumping system is used?

The chamber is evacuated by a 140 l/s turbomolecular pump and a mechanical pump, reaching a base pressure of 1 x 10^-7 Torr.[2][1]

Not publicly documented

The following facts about the Discovery 18 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Discovery 18 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Discovery 18 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Discovery 18 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Discovery 18 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Discovery 18 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]nanofab.utah.edu — nanofab.utah.edunanofab.utah.edu
  2. [2]web.archive.org — dentonvacuum.com (Nov 15, 1997)web.archive.org
  3. [3]nanofab.utah.edunanofab.utah.edu
  4. [4]nanofab.utah.edunanofab.utah.edu
Was this page accurate?

Last updated Sep 27, 2026.

Compare with similar tools

View all →