Metrology & InspectionHitachi S 4800 family
Research Quality: 50% complete

The Hitachi S 4800 I is a scanning electron microscope (SEM). The Hitachi S 4800 I achieves a resolution of 1.0 nm at 15 kV accelerating voltage and 2.0 nm at 1 kV. The Hitachi S 4800 I offers magnification from 30x to 800,000x in high-magnification mode.[1]

S 4800 I — Inventory photo
Fig. 01S 4800 IInventory photo[1]

What it is

The Hitachi S 4800 I is a scanning electron microscope used for metrology and inspection.[1]

The Hitachi S 4800 I includes a main body, a display unit with a PC, monitor, keyboard, and mouse, and a chiller as an option when no water source is present.[1]

How it works

General reference — not yet source-verified

A scanning electron microscope forms images by scanning a focused electron beam across a sample and collecting emitted signals from the interaction volume.

A scanning electron microscope uses electron optics, a vacuum column, and detectors to produce high-magnification images of surface features.

Where it fits in the process flow

General reference — not yet source-verified

A scanning electron microscope sits in the inspection and metrology flow, where it is used to examine surfaces, measure fine structural features, and review process results after fabrication steps.

What do the numbers mean?

Power & electrical1

Resolution
1.0 nm (Accelerating voltage: 15 kV, WD: 4mm; 2.0 nm (Accelerating voltage: 1 kV, WD: 1.5 mm)[1]
Accurate?

Vacuum & pumping2

Main body
1set including Tip, Objective aperture, Ion Pump, SE detection etc.[1]
Accurate?
Main body components
Tip, Objective aperture, Ion pump, SE detection[1]
Accurate?

Optics & imaging5

Magnification
30 to 2,000x in LM mode; 100 to 800,000 in HM mode[1]
Accurate?
Resolution (15 kV, WD 4mm)
1.0 nm[1]
Accurate?
Resolution (1 kV, WD 1.5 mm)
2.0 nm[1]
Accurate?
Magnification (LM mode)
30 to 2,000x[1]
Accurate?
Magnification (HM mode)
100 to 800,000x[1]
Accurate?

Control & software3

Diplay unit
1set including PC, monitor, keyboard, mouse, etc[1]
Accurate?
Operating system
Windows 2000[1]
Accurate?
Display unit components
PC, monitor, keyboard, mouse[1]
Accurate?

Configuration & options5

Chiller
Option if there is no water source[1]
Accurate?
Tilt motion:-5° to +70°[1]
Accurate?
Windows 2000[1]
Accurate?
Tilt motion
-5° to +70°[1]
Accurate?
Chiller
Optional if no water source[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Main body1set including Tip, Objective aperture, Ion Pump, SE detection etc.[1]
  • Resolution1.0 nm (Accelerating voltage: 15 kV, WD: 4mm; 2.0 nm (Accelerating voltage: 1 kV, WD: 1.5 mm)[1]
  • Main body componentsTip, Objective aperture, Ion pump, SE detection[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of instrument is the Hitachi S 4800 I?

The Hitachi S 4800 I is a scanning electron microscope.[1]

Not publicly documented

The following facts about the S 4800 I are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the S 4800 I are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the S 4800 I are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the S 4800 I are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the S 4800 I are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the S 4800 I is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]Inventory photo
Was this page accurate?

Last updated Oct 5, 2026.

Compare with similar tools

View all →