Keysight34401 A Multimeter
No photo available yet

Power

1000 V[1]

Performance

0.0035%[1]

Optics

6½ digits[1]

What it is

The Keysight 34401A is a digital multimeter for bench and system testing.[1]

The 34401A has 6½ digit resolution, ten measurement functions, and maximum input ratings of 1000 volts and 3 amperes.[1]

How it works

The 34401A measures direct current and alternating current voltage, direct current and alternating current current, two-wire resistance, four-wire resistance, diode voltage, continuity, frequency, and period.[1]

The 34401A uses a continuously integrating multi-slope analog-to-digital converter for direct voltage measurements.[1]

The 34401A supports GPIB and RS-232 interfaces as standard features and includes SCPI, Keysight 3478A, and Fluke8840A/42A command languages.[1]

Where it fits in the process flow

The 34401A is used for system testing with external trigger and voltmeter complete signals for synchronization to other instruments.[1]

Applications

The 34401A is used for voltage, current, resistance, diode, continuity, frequency, and period measurements.[1]

The 34401A is used on benchtops and in system test environments for fast, accurate measurement and data capture.[1]

What do the numbers mean?

Power & electrical3

Measurement functions
DC/AC voltage, DC/AC current, 2- and 4-wire resistance, diode, continuity, frequency, period[1]
Accurate?
Maximum voltage input
1000 V[1]
Accurate?
Power supply
100 V/120 V/220 V/240 V ± 10%[1]
Accurate?

Optics & imaging1

Resolution
6½ digits[1]
Accurate?

Performance2

Basic DC accuracy
0.0035%[1]
Accurate?
Basic AC accuracy
0.06%[1]
Accurate?

Control & software1

Interfaces
GPIB and RS-232[1]
Accurate?

Dimensions & facilities1

Weight
3.6 kg (8.0 lbs)[1]
Accurate?

Configuration & options9

Model
34401A[2]
Accurate?
Manufacturer
Keysight / Agilent[2]
Accurate?
Maximum current input
3 A[1]
Accurate?
Readings per second
1000 readings/second[1]
Accurate?
Reading memory
512 readings[1]
Accurate?
Programming languages
SCPI, Keysight 3478A, Fluke 8840A/42A[1]
Accurate?
Operating temperature
0 to 55 °C[1]
Accurate?
Storage temperature
-40 to 70 °C[1]
Accurate?
Warranty
3 year[1]
Accurate?

Vintage & configurations

  1. 2016-12-01End of life[1]

    The 34401A DMM and all associated options were discontinued on December 1, 2016.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Measurement functionsDC/AC voltage, DC/AC current, 2- and 4-wire resistance, diode, continuity, frequency, period[1]
  • Maximum voltage input1000 V[1]
  • Power supply100 V/120 V/220 V/240 V ± 10%[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What measurement functions does the 34401A provide?

The 34401A provides ten measurement functions: direct current voltage, alternating current voltage, direct current current, alternating current current, two-wire resistance, four-wire resistance, diode, continuity, frequency, and period.[1]

What is the maximum input rating of the 34401A?

The 34401A has a maximum voltage input of 1000 volts and a maximum current input of 3 amperes.[1]

What are the resolution and basic accuracy figures for the 34401A?

The 34401A has 6½ digit resolution, 0.0035 percent basic direct current accuracy, and 0.06 percent basic alternating current accuracy.[1]

What interface options are standard on the 34401A?

The 34401A includes GPIB and RS-232 interfaces as standard features.[1]

How much reading memory does the 34401A have?

The 34401A has 512 readings of internal memory.[1]

Was the 34401A discontinued?

The 34401A and all associated options were discontinued on December 1, 2016, and the last date the product could be ordered was November 30, 2016.[1][3]

Not publicly documented

The following facts about the 34401 A Multimeter are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 34401 A Multimeter are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 34401 A Multimeter are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 34401 A Multimeter are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 34401 A Multimeter is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 34401 A Multimeter are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]keysight.com — keysight.comkeysight.com
  2. [2]Equipment inventory listing
  3. [3]https://www.testequipmenthq.com/datasheets/Keysight-34401A-Datasheet.pdf — testequipmenthq.comtestequipmenthq.com
  4. [4]Equipment inventory listing
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools

View all →