Waferpedia

KLA

Altair 8920 Darkfield

Metrology & InspectionKLA Altair 8920 family
Research Quality: 50% complete
Altair 8920 Darkfield — Inventory photo
Fig. 01Altair 8920 DarkfieldInventory photo[1]

What it is

The KLA Altair 8920 is a darkfield inspection system that processes 8-inch wafers.[2][1]

How it works

General reference — not yet source-verified

Darkfield inspection works by directing a laser or broadband light source onto the wafer surface at an oblique angle. The specular reflection is blocked from reaching the detector, while light scattered by particles, pits, scratches, or pattern anomalies is collected and imaged. The system uses multiple collection channels, typically including forward-scatter and back-scatter optics, to capture different defect signatures.

The collected scatter signals are converted into electrical signals and processed by the system's image-analysis software. Defects are classified by size, type, and location using algorithms trained on reference die or golden images. The tool can operate in both brightfield and darkfield modes depending on configuration, but the Altair series is dedicated to darkfield detection.

Where it fits in the process flow

General reference — not yet source-verified

The tools sit between front-end-of-line and back-end-of-line processing, often as part of a defect-review workflow. Wafers rejected by darkfield inspection may be sent to review scanning electron microscopes or atomic-force microscopes for further analysis.

Applications

General reference — not yet source-verified

Common applications include incoming substrate qualification, post-chemical-mechanical planarization residue checks, defect-density monitoring after dielectric deposition, and post-etch inspection. The high throughput of automated darkfield systems makes them suitable for volume production environments.

What do the numbers mean?

Power & electrical2

Voltage
208 VAC[1]
Accurate?
Phase
3 Phase[1]
Accurate?

Wafer handling2

Handler
x3 FOUP with 8" adaptor plates[1]
Accurate?
Wafer Size
8 inch[2]
Accurate?

Configuration & options2

Largest Load
5.6[1]
Accurate?
Vintage
2019[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage208 VAC[1]
  • Phase3 Phase[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

How does darkfield inspection differ from brightfield inspection?General reference — not yet source-verified

Brightfield inspection captures directly reflected light, making it suitable for imaging fine pattern features and subtle reflectivity changes. Darkfield inspection captures only scattered light, providing higher sensitivity to discrete particles and small topographical defects on smooth surfaces.

What is the typical throughput of a darkfield inspection system?General reference — not yet source-verified

Throughput varies widely depending on the machine design, scanning speed, and defect sensitivity requirements. High-volume manufacturing systems are designed to inspect wafers in minutes per wafer for standard recipes, balancing speed with resolution.

Can darkfield inspection be used for patterned wafers?General reference — not yet source-verified

Yes, darkfield inspection is used for both unpatterned and patterned wafers. On patterned wafers, the technique is especially useful for detecting defects in low-topography structures or on film surfaces where pattern contrast is minimal.

What factors affect defect detection sensitivity in darkfield systems?General reference — not yet source-verified

Key factors include the angle and polarization of illumination, the numerical aperture of the collection optics, the wavelength of light, and the signal-to-noise ratio of the detector. System calibration and the reflectivity of the wafer surface also play important roles.

Not publicly documented

The following facts about the Altair 8920 Darkfield are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Altair 8920 Darkfield are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Altair 8920 Darkfield are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Altair 8920 Darkfield are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Altair 8920 Darkfield are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Altair 8920 Darkfield is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]Equipment inventory listing
Was this page accurate?

Last updated Oct 11, 2026.