Waferpedia

Tektronix

7603 Oscilloscope

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Tektronix 7603 is a 100 MHz analog oscilloscope mainframe from the Tektronix 7000 Series. The Tektronix 7603 accepts up to three 7-series plug-in modules for configuring vertical and horizontal measurement functions. The Tektronix 7603 includes a readout system that displays alphanumeric data from plug-in units on the CRT.[1][2][3]

7603 Oscilloscope — Inventory photo
Fig. 017603 OscilloscopeInventory photo[4]

Power

170 Watts (Max)[4]

Optics

CRT with graticule illumination[2]

What it is

The Tektronix 7603 is an analog oscilloscope mainframe that belongs to the Tektronix 7000 Series. The 7603 provides a bandwidth of 100 MHz. The mainframe incorporates a CRT display with an 8 x 10 division graticule; each division measures 1.22 centimeters. The 7603 accepts interchangeable 7000-series plug-in modules in three compartments: two vertical compartments and one horizontal compartment.[1][2][3]

How it works

The Tektronix 7603 operates as a modular analog oscilloscope mainframe. The instrument contains three compartments that accept Tektronix 7-series plug-in units. Two compartments on the left are connected to the vertical deflection system. The right compartment is connected to the horizontal deflection system. Electronic switching between the vertical plug-in compartments enables a multi-trace vertical display. The instrument includes a readout system that displays alphanumeric information from the plug-in units on the CRT. The maximum power consumption of the 7603 is 170 watts. The power supply accepts input frequencies from 48 Hz to 440 Hz.[4][3]

Applications

The Tektronix 7603 is designed for general-purpose measurement applications. The 7000 Series platform supports a wide range of plug-in modules, enabling configurations for dual-trace amplification, spectrum analysis, sampling, and logic probing. The mainframe's flexible architecture makes it suitable for use in electronics laboratories, universities, military test stations, and research and development facilities.[2][3]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • One source describes a unit with no display and no power in an as-is condition.

What do the numbers mean?

Power & electrical14

Power
170 Watts (Max)[4]
Accurate?
Current
1.9 Amps (Max)[4]
Accurate?
Frequency
48–440 Hz[4]
Accurate?
Bandwidth
100 MHz[1]2 sources
Accurate?
Power Consumption (Max)
170 Watts[4]
Accurate?
Current (Max)
1.9 Amps[4]
Accurate?
Frequency Range
48–440 Hz[4]
Accurate?
Maximum power consumption
170 Watts[4]
Accurate?
Maximum current
1.9 Amps[4]
Accurate?
Maximum power consumption
170 watts (60 hertz, 115-volt line)[3]
Accurate?
Power frequency
48–440 Hz[4]
Accurate?
Power consumption
170 Watts (Max)[4]
Accurate?
Maximum power consumption
About 170 watts (60 hertz, 115-volt line)[3]
Accurate?
Line frequency
48–440 Hz[4]
Accurate?

Optics & imaging3

Display Type
CRT with graticule illumination[2]
Accurate?
CRT graticule illumination
Yes[2]
Accurate?
Display
CRT with graticule illumination[2]
Accurate?

Control & software4

Readout system
CRT display of alphanumeric information from plug-in units[3]
Accurate?
Display
CRT, 8 x 10 divisions, each division 1.22 cm[3]
Accurate?
Display type
CRT, 8 x 10 divisions, 1.22 cm/division[3]
Accurate?
Display
Large-screen 8 x 10 division CRT display[3]
Accurate?

Dimensions & facilities6

Weight
50 lbs[1]
Accurate?
Dimensions
24 x 20 x 16 in[1]
Accurate?
Weight
40.00 LBS[2]
Accurate?
Dimensions
24 × 20 × 16 in[1]
Accurate?
Weight
50 lbs (22.7 kg)[1]
Accurate?
Dimensions
24 x 20 x 16 in (61 x 51 x 41 cm)[1]
Accurate?

Configuration & options36

Number of Plug-In Compartments
3 (two vertical, one horizontal)[3]
Accurate?
Display Size
8 x 10 divisions, each division 1.22 cm[3]
Accurate?
Form Factor
Benchtop mainframe[2]
Accurate?
Calibrator Output
Front panel calibrator output[2]
Accurate?
Cooling
Rear-mounted cooling fan[2]
Accurate?
Plug-in compatibility
Accepts Tektronix 7000-series plug-in modules[2]
Accurate?
Number of plug-in compartments
3[3]
Accurate?
Vertical deflection system
Two left compartments for vertical, right for horizontal[3]
Accurate?
Display size
8 x 10 division, each division 1.22 cm[3]
Accurate?
Cooling fan
Rear-mounted cooling fan[2]
Accurate?
Display size
8 x 10 divisions; each division equals 1.22 centimeters[3]
Accurate?
Number of input channels
Two input channels[1]
Accurate?
Dual timebase
Dual timebase[1]
Accurate?
Plug-in compartments
3 (two vertical, one horizontal)[3]
Accurate?
Power consumption (max)
170 W[4]
Accurate?
Power current (max)
1.9 A[4]
Accurate?
Form factor
Benchtop[2]
Accurate?
Calibrator output
Front panel[2]
Accurate?
Cooling fan
Rear-mounted[2]
Accurate?
Series
7000 Series[2]
Accurate?
Type
Analog oscilloscope mainframe[2]
Accurate?
Dual timebase
Supported with plug-in modules[1]
Accurate?
Input channels
2[1]
Accurate?
Dual timebase
Yes[1]
Accurate?
Plug-in compartments
3[3]
Accurate?
Make
Tektronix[4]
Accurate?
Model
7603[4]
Accurate?
Type
Oscilloscope[4]
Accurate?
Instrument type
Oscilloscope mainframe[2]
Accurate?
Technology
Solid state[3]
Accurate?
Use
General-purpose measuring applications[3]
Accurate?
Plug-in compartments
Three plug-in compartments for Tektronix 7-series plug-in units[3]
Accurate?
Channels
Two input channels[1]
Accurate?
Dual timebase
Present[1]
Accurate?
Compatible plug-in modules
Tektronix 7000-series plug-in modules[2]
Accurate?
Current (max)
1.9 A[4]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power170 Watts (Max)[4]
  • Current1.9 Amps (Max)[4]
  • Frequency48–440 Hz[4]
  • Bandwidth100 MHz[1]
  • Power Consumption (Max)170 Watts[4]
  • Current (Max)1.9 Amps[4]
  • Frequency Range48–440 Hz[4]
  • Maximum power consumption170 Watts[4]
  • Maximum current1.9 Amps[4]
  • Maximum power consumption170 watts (60 hertz, 115-volt line)[3]
  • Power frequency48–440 Hz[4]
  • Power consumption170 Watts (Max)[4]
  • Maximum power consumptionAbout 170 watts (60 hertz, 115-volt line)[3]
  • Line frequency48–440 Hz[4]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the bandwidth of the Tektronix 7603 oscilloscope?

The Tektronix 7603 mainframe has a bandwidth of 100 MHz.[2][1]

How many plug-in compartments does the 7603 have?

The 7603 has three plug-in compartments: two for vertical deflection and one for horizontal deflection.[3]

What is the display size of the 7603 CRT?

The CRT provides an 8 by 10 division display, with each division measuring 1.22 centimeters.[3]

What is the maximum power consumption of the Tektronix 7603?

Maximum power consumption is about 170 watts at 60 Hz and 115 volts line voltage.[3]

Not publicly documented

The following facts about the 7603 Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 7603 Oscilloscope are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 7603 Oscilloscope are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 7603 Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the 7603 Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 7603 Oscilloscope are on record.

    Answerable by: an OEM parts catalog or a service engineer

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]wyomingelectronics.com — wyomingelectronics.comwyomingelectronics.com
  2. [2]recycledgoods.com — recycledgoods.comrecycledgoods.com
  3. [3]opweb.de — opweb.deopweb.de
  4. [4]Inventory photo
Was this page accurate?

Last updated Oct 1, 2026.

Compare with similar tools

View all →