Waferpedia

Thermo Fisher

Scientific FEI Titan 80 300 TEM

The Scientific FEI Titan 80 300 TEM is a transmission electron microscope. The Titan 80 300 TEM uses a Schottky field emission gun as its electron source. The Titan 80 300 TEM includes a Cs (spherical aberration) image corrector to improve resolution.[1][2]

Scientific FEI Titan 80 300 TEM — Inventory photo
Fig. 01Scientific FEI Titan 80 300 TEMInventory photo[1]

Power

Alignments at 80kV and 300kV[1]

Performance

Alignments at 80kV and 300kV[1]

Optics

3-Condenser Lens System[1]

What it is

The Thermo Fisher Scientific FEI Titan 80 300 TEM is a transmission electron microscope equipped with a Schottky field emission gun, a three-condenser lens system, and a Cs image corrector with its own personal computer and power supply unit.[1][2]

The Titan 80 300 TEM includes a Bruker XFlash EDX detector with a standalone workstation, a Gatan Tridiem GIF for EELS and EFTEM, a Gatan DigiScan, a Gatan ADF/BF STEM detector, and a Fischione HAADF detector.[1][2]

The instrument is fitted with a US1000 bottom-mount CCD camera, a Lorentz lens for Lorentz TEM imaging, and an AAS at the C2 and objective aperture positions, along with manual apertures at the SA, C3, and C1 positions.[1][2]

How it works

The Titan 80 300 TEM can operate in bright-field, dark-field, and scanning TEM (STEM) modes using the Gatan ADF/BF STEM detector and the Fischione HAADF detector, and it supports electron energy-loss spectroscopy and energy-filtered TEM via the Gatan Tridiem GIF.[1][2]

Where it fits in the process flow

General reference — not yet source-verified

Transmission electron microscopes are used in semiconductor manufacturing for metrology, defect analysis, and process development, typically in a failure-analysis laboratory or a research environment rather than on the production line.

Applications

The Titan 80 300 TEM is employed for high-resolution transmission electron microscopy, scanning TEM, electron diffraction, and tomography, as enabled by its dedicated tomography software and free lens control software.[1][2]

Elemental analysis is performed with the Bruker XFlash EDX detector, and the Gatan Tridiem GIF provides electron energy-loss spectroscopy and energy-filtered TEM capabilities.[1][2]

What do the numbers mean?

Power & electrical3

Cs image corrector with image corrector PC and power supply unit[1]
Accurate?
Image corrector
Cs image corrector with image corrector PC and power supply unit[1]
Accurate?
Alignment voltages
Alignments at 80kV and 300kV[1]
Accurate?

Optics & imaging16

3-Condenser Lens System[1]
Accurate?
Bruker XFlash EDX Detector 6T – 100RT with a standalone workstation[1]
Accurate?
Gatan ADF/BF STEM detector[1]
Accurate?
Fischione HAADF detector[1]
Accurate?
US1000 Bottom mount CCD camera[1]
Accurate?
Lorentz Lens for Lorentz TEM imaging[1]
Accurate?
AAS at the C2 and objective aperture positions[1]
Accurate?
Free lens control software[1]
Accurate?
Condenser lens system
3-Condenser Lens System[1]
Accurate?
EDX detector
Bruker XFlash EDX Detector 6T – 100RT with a standalone workstation[1]
Accurate?
STEM detector (bright field / dark field)
Gatan ADF/BF STEM detector[1]
Accurate?
HAADF detector
Fischione HAADF detector[1]
Accurate?
CCD camera
US1000 Bottom mount CCD camera[1]
Accurate?
Lorentz lens
Lorentz Lens for Lorentz TEM imaging[1]
Accurate?
Aperture alignment system
AAS at the C2 and objective aperture positions[1]
Accurate?
Lens control software
Free lens control software[1]
Accurate?

Performance1

Alignments at 80kV and 300kV[1]
Accurate?

Control & software8

TrueImage software[1]
Accurate?
Gatan DigitalMicrograph software[1]
Accurate?
FEI TIA software[1]
Accurate?
Tomography software[1]
Accurate?
Imaging software
TrueImage software[1]
Accurate?
STEM software
Gatan DigitalMicrograph software[1]
Accurate?
TEM imaging software
FEI TIA software[1]
Accurate?
Tomography software
Tomography software[1]
Accurate?

Configuration & options12

Schottky FEG[1]
Accurate?
Gatan Tridiem GIF capable of EELS and EFTEM[1]
Accurate?
Gatan DigiScan[1]
Accurate?
Manual apertures at SA, C3, and C1 aperture positions[1]
Accurate?
Haskris Chiller Model R175EW[1]
Accurate?
Toshiba UPS 4200FA with a Power Battery Company UPS battery supply[1]
Accurate?
Electron source
Schottky FEG[1]
Accurate?
Energy filter / EELS
Gatan Tridiem GIF capable of EELS and EFTEM[1]
Accurate?
STEM scanning
Gatan DigiScan[1]
Accurate?
Manual apertures
Manual apertures at SA, C3, and C1 aperture positions[1]
Accurate?
Chiller
Haskris Chiller Model R175EW[1]
Accurate?
UPS
Toshiba UPS 4200FA with a Power Battery Company UPS battery supply[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationCs image corrector with image corrector PC and power supply unit[1]
  • Image correctorCs image corrector with image corrector PC and power supply unit[1]
  • Alignment voltagesAlignments at 80kV and 300kV[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Scientific FEI Titan 80 300 TEM are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Scientific FEI Titan 80 300 TEM are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Scientific FEI Titan 80 300 TEM are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Scientific FEI Titan 80 300 TEM are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Scientific FEI Titan 80 300 TEM are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Scientific FEI Titan 80 300 TEM is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.