The Thermo Fisher Scientific Lab Line Vacuum is a vacuum oven line. The Thermo Fisher Scientific Lab Line Vacuum includes a 3628A model with a 1.5 cu.ft. capacity. The Thermo Fisher Scientific Lab Line Vacuum includes a 3618-5 model with a 2.3 cu.ft. capacity.[1][2][3]

Scientific Lab Line Vacuum — Inventory photo
Fig. 01Scientific Lab Line VacuumInventory photo[1]

Power

120V[2]

Vacuum

Vacuum Oven[2]

What it is

General reference — not yet source-verified

The Thermo Fisher Scientific Lab Line Vacuum is a vacuum oven used for controlled heating under reduced pressure.

How it works

The Lab-Line vacuum oven uses warm-wall heating, vacuum and purge controls, and corrosion-resistant stainless-steel vacuum and air lines.[3]

The 3618-5 model uses a hydraulic thermostat temperature control with a dial thermometer, and the 3628A model uses a single set-point controller with a seven-day programmable timer and dual displays.[3][2]

Where it fits in the process flow

A vacuum oven fits in drying, curing, vacuum embedding, plating, process control, and inert-atmosphere workflows.[3][2]

Applications

The Lab-Line vacuum oven is used for desiccation and for drying processes that benefit from reduced pressure.[2]

The Lab-Line vacuum oven is also used for vacuum embedding, plating, curing, process control, and inert-atmosphere processing.[3][2]

What do the numbers mean?

Power & electrical6

Voltage
120V[2]
Accurate?
Amperage
12A[2]
Accurate?
Wattage
1400w[2]
Accurate?
Amperage
13.3A[3]
Accurate?
Wattage
1600w[3]
Accurate?
Hertz
50/60 Hz[2]
Accurate?

Vacuum & pumping2

Type
Vacuum Oven[2]
Accurate?
Equipment type
Vacuum oven[1]
Accurate?

Control & software2

Control/display
LED display[3]
Accurate?
Control/display
Dial thermometer with hydraulic thermostat control[3]
Accurate?

Configuration & options13

Make
Thermo Fisher Scientific[1]
Accurate?
Model
Lab Line[1]
Accurate?
Capacity
1.5 cu.ft. (42.4L)[2]
Accurate?
Frequency
50/60Hz[2]
Accurate?
Temperature Range
50° to 280°C[2]
Accurate?
Display
LED[2]
Accurate?
Capacity
2.3 cu.ft. (65.1L)[3]
Accurate?
Temperature Range
Ambient +10° to 220°C[3]
Accurate?
Display
LED with 1°C increments[3]
Accurate?
Temperature range
Ambient +10°C to 280°C[2]
Accurate?
Temperature range
Ambient +10°C to 220°C[3]
Accurate?
Chamber material
Stainless steel[2]
Accurate?
Cabinet material
Powder-coated heavy-gauge steel[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
3628A——1.5 cu.ft. capacity, 120V, 50/60Hz, 12A, 1400w, LED display.thermobid.com[2]
3618-5——2.3 cu.ft. capacity, 120V, 50/60Hz, 13.3A, 1600w, LED display with 1°C increments.thermobid.com[3]
3625A——0.65 cu. ft. capacity, LED display, 120V 50/60Hz.thermobid.com[2]
3625A-1——0.65 cu. ft. capacity, LED display, 240V 50/60Hz.thermobid.com[2]
3628A-1——1.5 cu. ft. capacity, LED display, 240V 50/60Hz.thermobid.com[2]
3606——0.44 cu. ft. capacity, dial display, 120V 50/60Hz.thermobid.com[3]
3606-1CE——0.44 cu. ft. capacity, dial display, 240V 50/60Hz.thermobid.com[3]
3608——0.7 cu. ft. capacity, dial display, 120V 50/60Hz.thermobid.com[3]
3608-1CE——0.7 cu. ft. capacity, dial display, 240V 50/60Hz.thermobid.com[3]
3608-5——0.7 cu. ft. capacity, LED display, 120V 50/60Hz.thermobid.com[3]
3608-6CE——0.7 cu. ft. capacity, LED display, 240V 50/60Hz.thermobid.com[3]
3618——2.3 cu. ft. capacity, dial display, 120V 50/60Hz.thermobid.com[3]
3618-1CE——2.3 cu. ft. capacity, dial display, 240V 50/60Hz.thermobid.com[3]
3618-6CE——2.3 cu. ft. capacity, LED display, 240V 50/60Hz.thermobid.com[3]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • TypeVacuum Oven[2]
  • Voltage120V[2]
  • Amperage12A[2]
  • Wattage1400w[2]
  • Amperage13.3A[3]
  • Wattage1600w[3]
  • Equipment typeVacuum oven[1]
  • Hertz50/60 Hz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What sample sizes can such equipment handle?General reference — not yet source-verified

Lab-scale systems are designed to accommodate samples ranging from small substrates to standard wafer sizes used in research, though exact dimensions vary by model. The chamber size is typically optimized for single or small-batch processing.

How is temperature uniformity maintained in the chamber?General reference — not yet source-verified

Uniformity is achieved through multi-zone heating elements, careful insulation, and feedback control from thermocouples. The vacuum environment also reduces convective heat loss, aiding in even temperature distribution across the sample.

Not publicly documented

The following facts about the Scientific Lab Line Vacuum are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Scientific Lab Line Vacuum are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Scientific Lab Line Vacuum are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Scientific Lab Line Vacuum are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Scientific Lab Line Vacuum is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Scientific Lab Line Vacuum are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]thermobid.com — thermobid.comthermobid.com
  3. [3]thermobid.com — thermobid.comthermobid.com
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →