Waferpedia

ASML

PAS 5500 300 C DUV

LithographyASML PAS 5500 family
Research Quality: 60% complete

The ASML PAS 5500/300 C DUV is a deep-ultraviolet wafer stepper. The ASML PAS 5500/300 C DUV uses a 248 nm lens column with 0.63 N.A. The ASML PAS 5500/300 C DUV accommodates wafer sizes from 3 inch up to 200 mm.[1][2]

PAS 5500 300 C DUV — Inventory photo
Fig. 01PAS 5500 300 C DUVInventory photo[2]

Performance

3D-Align backside alignment[1]

Optics

Upgrade to 5500/300C via lens upgrade[2]

What it is

The ASML PAS 5500 300 C DUV is a deep ultraviolet wafer stepper used for photolithographic pattern transfer in semiconductor fabrication.[2][1]

The ASML PAS 5500 300 C DUV is a projection printer in the photolithography section of the process flow.[1]

How it works

The ASML PAS 5500 300 C DUV uses a DUV lens column at two hundred forty eight nanometers and a Zeiss lens with variable numerical aperture.[1]

The ASML PAS 5500 300 C DUV performs step and repeat exposure with laser-controlled stage motion.[1]

The ASML PAS 5500 300 C DUV supports annular illumination modes and backside alignment.[1]

Where it fits in the process flow

General reference — not yet source-verified

The ASML PAS 5500 300 C DUV sits in the lithography module of the fab flow, where it exposes patterned resist on a wafer before later pattern transfer steps.

The ASML PAS 5500 300 C DUV is used after mask preparation and resist coating and before subsequent development and etch or deposition steps.

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Stage interferometer needs to be replaced.

What do the numbers mean?

Wafer handling3

Wafer sizes
8 inch[2]
Accurate?
Wafer size range
3 inch up to 200 mm[1]
Accurate?
Wafer Size Range
3" up to 200mm[1]
Accurate?

Optics & imaging17

Upgrade to 5500/300C via lens upgrade[2]
Accurate?
Cymer 5600 Laser[2]
Accurate?
Laser Chamber changed[2]
Accurate?
Laser Path Optics recently replaced[2]
Accurate?
ASML test reticles[2]
Accurate?
Reticle error compensation[2]
Accurate?
Exposure wavelength
248 nm[1]
Accurate?
Lens column
DUV (248nm), 0.63 N.A.[1]
Accurate?
Exposure field size
up to 22 mm square[1]
Accurate?
Mask size
6 inch x 0.250 inch thick quartz masks[1]
Accurate?
Stage motion
laser-controlled stage motion[1]
Accurate?
Illumination
programmable annular illumination modes[1]
Accurate?
Exposure Wavelength
248nm (DUV)[1]
Accurate?
Lens Numerical Aperture
0.63 - 0.40 variable[1]
Accurate?
Exposure Field Size
22 mm x 22 mm[1]
Accurate?
Mask Size
6" x0.250"- thick quartz masks[1]
Accurate?
Laser Source
Cymr 5600 Laser[2]
Accurate?

Performance2

Alignment
Registered alignment is typically <0.045 µm, even when using backside alignment[1]
Accurate?
Backside alignment
3D-Align backside alignment[1]
Accurate?

Configuration & options23

Can be configured for 3" - 6"[2]
Accurate?
Upgraded workstation[2]
Accurate?
Extended N/A Option[2]
Accurate?
Stage Interferometer Bad[2]
Accurate?
CM Options:[2]
Accurate?
REFL Img Sensor[2]
Accurate?
PEP 1 Productivity upgrade[2]
Accurate?
PEP 2 productivity upgrade[2]
Accurate?
Flatness Model[2]
Accurate?
LSQ Disto Model[2]
Accurate?
Mark sensor[2]
Accurate?
Batch streaming[2]
Accurate?
Intensity 2[2]
Accurate?
Aerial Key[2]
Accurate?
OEM
ASML[2]
Accurate?
Model
PAS 5500 / 300 C[2]
Accurate?
Tool type
DUV Stepper (Deep Ultraviolet)[2]
Accurate?
Reduction
4:1[1]
Accurate?
Minimum feature size
<0.20 µm[1]
Accurate?
Reduction Ratio
4:1[1]
Accurate?
Registered Algnment
Typically <0.045 µm[1]
Accurate?
Wafter Size (from listing)
8 inch[2]
Accurate?
Vintage Year
1996[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
PAS 5500/300CDUV1996Can be configured for 3 inch to 6 inch wafers; upgrade to 5500/300C via lens upgrade; upgraded workstation; extended N/A option; Cymer 5600 laser; laser chamber changed; laser path optics recently replaced; CM options listed include REFL Img Sensor, PEP 1, PEP 2, reticle error compensation, flatness model, LSQ Disto Model, mark sensor, batch streaming, intensity 2, aerial key, extended NA range, focal adjustment, alignment reports, annular illumination, scribblelane marks, library, and visual alignment camera.Equipment inventory listing[2]
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Publicly hosted documents referencing this tool, linked at their original location. Hosted by the linked institutions — availability may change.

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the minimum feature size achievable?

Minimum feature size is less than 0.20 µm.[1]

What wafer sizes are supported?

Wafer sizes from 3 inches up to 200 mm can be accommodated.[1]

What is the reduction ratio of the lens?

The lens provides a 4:1 reduction.[1]

What is the exposure field size?

The field size is 22 mm by 22 mm.[1]

What type of masks does the system use?

The system uses 6-inch by 0.250-inch thick quartz masks.[1]

Not publicly documented

The following facts about the PAS 5500 300 C DUV are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the PAS 5500 300 C DUV are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the PAS 5500 300 C DUV are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the PAS 5500 300 C DUV is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the PAS 5500 300 C DUV are on record.

    Answerable by: an OEM parts catalog or a service engineer

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]cnfusers.cornell.edu — cnfusers.cornell.educnfusers.cornell.edu
  2. [2]Inventory photo
  3. [3]Equipment Resources | CNF — cnf.cornell.educnf.cornell.edu
Was this page accurate?

Last updated Oct 11, 2026.

Compare with similar tools

View all →