The Edwards iH1000 is a dry vacuum pumping system that uses an HCDP80 dry pump with an HCMB1000 mechanical booster pump, achieving a peak pumping speed of 1000 m³/h at 60 Hz. The iH1000 is part of the iH series of dry pumping systems from Edwards (formerly BOC Edwards).[1]

The iH dry pumping system uses a HCDP dry pump as the primary pumping stage. For the iH1000, this is supplemented by a HCMB mechanical booster pump to increase pumping speed at lower pressures.[1]
The system is designed with a temperature control system for both the HCDP and HCMB pumps, and includes connections for nitrogen purge and cooling water to manage process gases and thermal load. The pumping system is controlled by an electronics module and a pump display terminal.[1]
Dry pumps in this class use claw or screw mechanisms to compress gas without lubricants, making them suitable for clean vacuum environments. The iH series includes features such as gas modules, exhaust systems, and safety sensors.[1]
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| IH 1000 Pump - Without Invrt - Fully refurbished | — | — | Described as without inverter and fully refurbished. | Equipment inventory listing[4] |
| IH 1000 Pump - With Invrt | — | — | Described as with inverter. | Equipment inventory listing[2] |
| IH 1000 Pump - Rear | — | — | Described as rear. | Equipment inventory listing[3] |
| iH1000F | — | — | Includes Breach Sensor for leak detection during run 'til crash. | nanofab.utah.edu[1] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Publicly hosted documents referencing this tool, linked at their original location. Hosted by the linked institutions — availability may change.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The IH 1000 combines an HCDP dry pump with an HCMB mechanical booster pump. The HCMB booster is fitted on the iH600 and iH1000 systems only.[1]
The IH 1000 requires a nitrogen supply, cooling-water connections, and an electrical supply. Optional accessories include an enclosure extraction fan and alternative nitrogen and cooling-water connection kits.[1]
The iH dry pumping systems are declared compliant with the ATEX directive as Category 3GD equipment for internal atmospheres only.[1]
Maintenance includes checking and changing the oil in the HCDP pump and the HCMB pump on iH600 and iH1000 systems. Maintenance also includes checking purge-gas flow rates, inspecting and cleaning the exhaust pipe, and zeroing the gas-module flow transducer.[1]
The following facts about the IH 1000 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the IH 1000 are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the IH 1000 are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the IH 1000 are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the IH 1000 is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the IH 1000 are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Oct 4, 2026.